Entry  Fri Jan 24 11:03:14 2014, Wolfgang Treberspurg, AIDA, AIDA, HW_AIDA002, 0, 24.01.2014 10:02, , Crap 
TuxDaq crashed
Entry  Fri Jan 24 18:02:46 2014, Wolfgang Treberspurg, Infineon, New Infineon Stack, , , , , Good 
Exchanged AIDA stack with modified Infineon Stack 
Configuration: 
Beam   Infineon_TB_2014_Baby1(P0)   ---   Inifineon_TB_2014_Baby2(P1) |||  Infineon_TB_2012_Baby2(P2)  --- Infineon_TB_2012_Baby1(P3)
Entry  Sat Jan 25 18:24:03 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2, HW_Run_Infineon_Stack2_001, 1.05 M, 25.01.2014 10:30, 25.01.2014 15:40, Unknown 
HV at 300V; I at app. 11µA 4GeV, Single mode
Modules centered to beam but no hits at additional Strixel modul. Perhaps HV problems (High noise of Strixel almost did not change after biasing)
-> HV connection will be checked at next opportunity to enter area.
Entry  Sat Jan 25 18:28:38 2014, Wolfgang Treberspurg, Infineon, Calibration run Infineon Stack 2, Calibration_Run_Infineon_Stack2_001, 82900, 25.01.2014 10:15, 25.01.2014 10:25, Unknown 
HV 300V, I ca. 11µA single mode
Entry  Sat Jan 25 18:46:32 2014, Wolfgang Treberspurg, Infineon, Mulit 6 mode Run Stack 2, HW_Run_Infineon_Stack2_Multi_001, 340k, 25.01.2014 16:30, 25.01.2014 18:40, Unknown 
HV 300V, I 10µA
Beam Energy changed during the run between 2GeV - 5GeV - 4GeV
Latency perhaps not optimal set (has been 95) but exchanged trigger cable seems to require 93
Entry  Sat Jan 25 21:14:46 2014, Wolfgang Treberspurg, Infineon, Mulit 6 mode Run Stack 2, HW_Run_Infineon_Stack2_Multi_002, 230k, 25.01.2014 19:00, 25.01.2014 21:15, Good 
HV 300V, I 10µA
Beam Energy  4GeV
Latency changed to 93
Entry  Sun Jan 26 19:12:42 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2, HW_Run_Infineon_Stack2_002, 4 M, 25.01.2014 22:30, 26.01.2014 15:15, Good 
HV at 300V; I at app. 11µA 4GeV, Single mode
 
Entry  Sun Jan 26 19:14:07 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2, HW_Run_Infineon_Stack2_003, 140 k, 26.01.2014 18:10, 26.01.2014 19:15, Good 
HV at 300V; I at app. 10µA 5GeV, Single mode
 
Entry  Mon Jan 27 12:20:53 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2, HW_Run_Infineon_Stack2_004, 800k, 27.01.2014 09:10, 27.01.2014 12:15, Good 
HV at 300V; I at app. 10µA 3GeV, Single mode
 
Entry  Wed Jan 29 12:02:52 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_001, 100k, 28.01.2014 16:30, 28.01.2014 16:50, Good 
HV at 0V; I at app. 5nA 3GeV, Single mode
 
Entry  Wed Jan 29 12:04:53 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_002, 140k, 28.01.2014 16:50, 28.01.2014 17:20, Good 
HV at 100V; I at app. 8.5µA 3GeV, Single mode
 
Entry  Wed Jan 29 12:07:48 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_003, 200k, 28.01.2014 17:40, 28.01.2014 18:20, Good 
HV at 150V; I at app. 9µA 3GeV, Single mode
 
Entry  Wed Jan 29 12:08:52 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_004, 200k, 28.01.2014 19:30, 28.01.2014 20:00, Good 
HV at 200V; I at app. 9.5µA 3GeV, Single mode
 
Entry  Wed Jan 29 12:10:06 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_005, 200k, 28.01.2014 20:00, 28.01.2014 23:00, Good 
HV at 210V; I at app. 8.5µA 3GeV, Single mode
 
Entry  Wed Jan 29 12:11:00 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_006, 200k, 28.01.2014 20:30, 28.01.2014 21:00, Good 
HV at 220V; I at app. 8.5µA 3GeV, Single mode
 
Entry  Wed Jan 29 21:55:09 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_007, 200k, 29.01.2014 11:50, 29.01.2014 12:15, Good 
HV at 230V; I at app. 8µA 3GeV, Single mode
 
Entry  Wed Jan 29 21:56:15 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_008, 200k, 29.01.2014 12:15, 29.01.2014 12:45, Good 
HV at 240V; I at app. 7.5µA 3GeV, Single mode
 
Entry  Wed Jan 29 21:56:58 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_009, 110k, 29.01.2014 12:50, 29.01.2014 13:15, Good 
HV at 250V; I at app. 7.5µA 3GeV, Single mode
 
Entry  Wed Jan 29 21:57:55 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_010, 100k, 29.01.2014 13:20, 29.01.2014 13:35, Good 
HV at 260V; I at app. 7.6µA 3GeV, Single mode
 
Entry  Wed Jan 29 21:59:51 2014, Wolfgang Treberspurg, Infineon, Single mode Run Stack 2 Bias Scan, HW_Run_Infineon_Stack2_BiasScan_011, 200k, 29.01.2014 13:45, 29.01.2014 14:20, Good 
HV at 270V; I at app. 7.6µA 3GeV, Single mode
 