  Alibava testbeam at DESY in Oct. 2017 (Dominic, Peter), Page 3 of 7  Not logged in ELOG logo
ID Date Author DUT Subject Run Number Eventsup XYPosition Cooling Data
  109   Tue Oct 24 18:46:33 2017 Peter PaulitschHPK_200_1e15run000334334101000076.50, 66.00, 0°YesGood
Parameter Value
Alibava filename  run000334.dat
Telescope filename  run000334.raw
Pedestal filename KIT_pedestal_600V_22102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 76.50, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  113   Mon Oct 30 11:40:27 2017 Peter PaulitschHPK_200_1e15run000342342101000075.00, 66.00, -30°YesGood
Parameter Value
Alibava filename  run000342.dat
Telescope filename  run000342.raw
Pedestal filename KIT_pedestal_600V_23102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.00, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  115   Mon Oct 30 11:41:46 2017 Peter PaulitschHPK_200_1e15run000346346101000075.00, 66.00, -20°YesGood
Parameter Value
Alibava filename  run000346.dat
Telescope filename  run000346.raw
Pedestal filename KIT_pedestal_600V_23102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.00, 66.00
Region of interest bias line
Trigger frequency  135 Hz
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  117   Mon Oct 30 11:43:29 2017 Peter PaulitschHPK_200_1e15run000350350101000076.50, 66.00, -10°YesGood
Parameter Value
Alibava filename  run000350.dat
Telescope filename  run000350.raw
Pedestal filename KIT_pedestal_600V_23102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 76.50, 66.00
Region of interest bias line
Trigger frequency  135 Hz
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  119   Mon Oct 30 11:45:40 2017 Peter PaulitschHPK_200_1e15run000355355101000076.50, 66.00, 0°YesGood
Parameter Value
Alibava filename  run000355.dat
Telescope filename  run000355.raw
Pedestal filename KIT_pedestal_600V_23102017.ped
Bias voltage -400 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 76.50, 66.00
Region of interest bias line
Trigger frequency  135 Hz
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  120   Mon Oct 30 11:46:30 2017 Peter PaulitschHPK_200_1e15run000357357101000076.50, 66.00, 0°YesGood
Parameter Value
Alibava filename  run000357.dat
Telescope filename  run000357.raw
Pedestal filename KIT_pedestal_600V_23102017.ped
Bias voltage -500 V
Dark current 132 uA
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 76.50, 66.00
Region of interest bias line
Trigger frequency  135 Hz
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  121   Mon Oct 30 11:47:32 2017 Peter PaulitschHPK_200_1e15run000362362101000076.50, 66.00, -5°YesGood
Parameter Value
Alibava filename  run000362.dat
Telescope filename  run000362.raw
Pedestal filename KIT_pedestal_600V_23102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 3010000
Telescope triggers 3000000
Data synced yes
Table position x/y 76.50, 66.00
Region of interest bias line
Trigger frequency  135 Hz
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  125   Mon Oct 30 11:52:26 2017 Peter PaulitschIFX_200_1e15run000373373101000075.00, 66.00, -30°YesGood
Parameter Value
Alibava filename  run000373.dat
Telescope filename  run000373.raw
Pedestal filename KIT_pedestal_600V_26102017.ped
Bias voltage -600 V
Dark current 100 uA
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.00, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  126   Mon Oct 30 11:53:33 2017 Peter PaulitschIFX_200_1e15run000375375101000075.00, 66.00, -20°YesGood
Parameter Value
Alibava filename  run000375.dat
Telescope filename  run000375.raw
Pedestal filename KIT_pedestal_600V_26102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.00, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  127   Mon Oct 30 11:54:14 2017 Peter PaulitschIFX_200_1e15run000377377101000076.50, 66.00, -10°YesGood
Parameter Value
Alibava filename  run000377.dat
Telescope filename  run000377.raw
Pedestal filename KIT_pedestal_600V_26102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 76.50, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.7%
  130   Mon Oct 30 12:02:05 2017 Peter PaulitschIFX_200_1e15run000384384101000076.50, 66.00, 0°YesGood
Parameter Value
Alibava filename  run000384.dat
Telescope filename  run000384.raw
Pedestal filename KIT_pedestal_600V_26102017.ped
Bias voltage -500 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 76.50, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  131   Mon Oct 30 12:02:54 2017 Peter PaulitschIFX_200_1e15run000387387101000076.50, 66.00, 0°YesGood
Parameter Value
Alibava filename  run000387.dat
Telescope filename  run000387.raw
Pedestal filename KIT_pedestal_600V_26102017.ped
Bias voltage -800 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 76.50, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  132   Mon Oct 30 12:03:27 2017 Peter PaulitschIFX_200_1e15run000388388101000076.50, 66.00, 0°YesGood
Parameter Value
Alibava filename  run000388.dat
Telescope filename  run000388.raw
Pedestal filename KIT_pedestal_600V_26102017.ped
Bias voltage -400 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 76.50, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  92   Tue Oct 24 18:26:24 2017 Peter PaulitschHPK_3e14run0003073071010000, ALiBaVa crashed75.50, 66.00, -30°YesGood
Parameter Value
Alibava filename  run000307.dat
Telescope filename  run000307.raw
Pedestal filename KIT_pedestal_600V_22102017.ped
Bias voltage -600 V
Dark current 35 uA
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.50, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  10   Wed Oct 18 12:22:03 2017 Peter PaulitschIFX_CenterBiasrun00009999110000122.9, 23.5, -3.3°NoGood
run settings
Parameter Value
Alibava filename  run000099.dat
Telescope filename  run000099.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -160 nA
Sensor temperature 24.6 °C
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 122.9, 23.5
Region of interest bias line
Trigger frequency  185 Hz
Meas. time 17 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 52.3%

 

  12   Wed Oct 18 13:29:39 2017 Peter PaulitschIFX_CenterBiasrun000102102110000122.9, 23.2, -3.3°NoGood
run settings
Parameter Value
Alibava filename  run000102.dat
Telescope filename  run000102.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -160 nA
Sensor temperature 24.6 °C
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 122.9, 23.8
Region of interest bias line
Trigger frequency  185 Hz
Meas. time 17 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 52.3%

 

  13   Wed Oct 18 13:30:58 2017 Peter PaulitschIFX_CenterBiasrun000104104110000122.9, 23.5, -3.3°NoUnknown
run settings
Parameter Value
Alibava filename  run000104.dat
Telescope filename  run000104.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -160 nA
Sensor temperature 24.6 °C
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 122.9, 23.5
Region of interest bias line
Trigger frequency  200 Hz
Meas. time 15 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 52.3%

 

  15   Wed Oct 18 13:34:54 2017 Peter PaulitschIFX_CenterBiasrun000107107110000122.9, 23.5, -3.3°NoGood
run settings
Parameter Value
Alibava filename  run000107.dat
Telescope filename  run000107.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -160 nA
Sensor temperature 24.6 °C
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 122.9, 23.5
Region of interest bias line
Trigger frequency  200 Hz
Meas. time 15 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 53.4%

 

  16   Wed Oct 18 13:36:50 2017 Peter PaulitschIFX_CenterBiasrun000109109110000122.9, 25.75, -3.3°NoGood
run settings
Parameter Value
Alibava filename  run000109.dat
Telescope filename  run000109.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -160 nA
Sensor temperature 24.6 °C
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 122.9, 25.75
Region of interest bias line
Trigger frequency  200 Hz
Meas. time 15 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 53.4%

 

  18   Fri Oct 20 12:15:47 2017 Peter PaulitschIFX_200_3e14run00011611611000075.93, 63.00, -72.55°YesGood
run settings
Parameter Value
Alibava filename  run000116.dat
Telescope filename  run000116.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 39 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 63.00
Region of interest bias line
Trigger frequency  210 Hz
Meas. time 15 min
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.2%

 