  Alibava testbeam at DESY in Oct. 2017 (Dominic, Peter), Page 3 of 7  Not logged in ELOG logo
ID Date Author DUT Subject Run Number Eventsdown XYPosition Cooling Data
  19   Fri Oct 20 14:05:39 2017 Peter PaulitschIFX_200_3e14run00011811811000075.93, 61.20, -72.55°YesGood
run settings
Parameter Value
Alibava filename  run000118.dat
Telescope filename  run000118.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 39 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 61.20
Region of interest bias line
Trigger frequency  210 Hz
Meas. time 15 min
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.2%

 

  20   Fri Oct 20 14:09:11 2017 Peter PaulitschIFX_200_3e14run00012012011000075.93, 64.80, -72.55°YesGood
run settings
Parameter Value
Alibava filename  run000120.dat
Telescope filename  run000120.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 39 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 64.80
Region of interest bias line
Trigger frequency  210 Hz
Meas. time 15 min
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.5%

 

  21   Fri Oct 20 14:11:03 2017 Peter PaulitschIFX_200_3e14run00012212211000075.93, 65.30, -72.55°YesGood
run settings
Parameter Value
Alibava filename  run000122.dat
Telescope filename  run000122.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 39 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency  210 Hz
Meas. time 15 min
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.7%

 

  22   Fri Oct 20 14:12:20 2017 Peter PaulitschIFX_200_3e14run00012412411000075.93, 65.30, -72.55°YesGood
run settings
Parameter Value
Alibava filename  run000124.dat
Telescope filename  run000124.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 39 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency  210 Hz
Meas. time 15 min
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.3%

 

  23   Fri Oct 20 14:14:15 2017 Peter PaulitschIFX_200_3e14run00016216211000075.93, 65.30, -70.55°YesGood
run settings
Parameter Value
Alibava filename  run000162.dat
Telescope filename  run000162.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 90 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency  250 Hz
Meas. time 12 min
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.2%

 

  24   Fri Oct 20 14:16:03 2017 Peter PaulitschIFX_200_3e14run00016416411000075.93, 65.30, -70.55°YesGood
run settings
Parameter Value
Alibava filename  run000164.dat
Telescope filename  run000164.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 90 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 110000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency  250 Hz
Meas. time 12 min
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.5%

 

  25   Fri Oct 20 14:23:59 2017 Peter PaulitschIFX_200_3e14run00016616611000075.93, 65.30, -70.55°YesGood
run settings
Parameter Value
Alibava filename  run000166.dat
Telescope filename  run000166.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 90 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.2%

 

  26   Fri Oct 20 14:26:59 2017 Peter PaulitschIFX_200_3e14run00016916911000075.93, 65.30, -70.55°YesGood
run settings
Parameter Value
Alibava filename  run000169.dat
Telescope filename  run000169.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 90 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.5%

 

  27   Fri Oct 20 14:29:57 2017 Peter PaulitschIFX_200_3e14run00017317311000075.93, 65.30, -70.55°YesGood
run settings
Parameter Value
Alibava filename  run000173.dat
Telescope filename  run000173.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 90 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.2%

 

  43   Fri Oct 20 15:32:27 2017 Peter PaulitschIFX_200_3e14run00020820811000075.93, 65.30, -80.55°YesGood
run settings
Parameter Value
Alibava filename  run000208.dat
Telescope filename  run000208.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.1%

 

  46   Fri Oct 20 15:37:26 2017 Peter PaulitschIFX_200_3e14run00021721711000075.93, 65.30, -70.55°YesGood
run settings
Parameter Value
Alibava filename  run000217.dat
Telescope filename  run000217.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current 40 uA
Sensor temperature -6
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.8%

 

  64   Tue Oct 24 17:46:11 2017 Peter PaulitschHPK_3e14run00024424411000075.93, 65.30, -100.55°YesGood
Parameter Value
Alibava filename  run000244.dat
Telescope filename  run000244.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 46.1%
  67   Tue Oct 24 17:53:19 2017 Peter PaulitschHPK_3e14run00024824811000075.93, 65.30, -90.55°YesGood
Parameter Value
Alibava filename  run000248.dat
Telescope filename  run000248.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  69   Tue Oct 24 17:57:28 2017 Peter PaulitschHPK_3e14run00025125111000075.93, 65.30, -80.55°YesGood
Parameter Value
Alibava filename  run000251.dat
Telescope filename  run000251.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  70   Tue Oct 24 17:58:09 2017 Peter PaulitschHPK_3e14run00025525511000075.93, 65.30, -80.55°YesGood
Parameter Value
Alibava filename  run000255.dat
Telescope filename  run000255.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  72   Tue Oct 24 17:59:58 2017 Peter PaulitschHPK_3e14run00025925911000075.93, 65.30, -70.55°YesGood
Parameter Value
Alibava filename  run000259.dat
Telescope filename  run000259.raw
Pedestal filename KIT_pedestal_600V_20102017.ped
Bias voltage -500 V
Dark current 37 uA
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.93, 65.30
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  75   Tue Oct 24 18:02:47 2017 Peter PaulitschHPK_200run000264264110000NoGood
Parameter Value
Alibava filename  run000264.dat
Telescope filename  run000264.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  76   Tue Oct 24 18:04:09 2017 Peter PaulitschHPK_200run000266266110000NoGood
Parameter Value
Alibava filename  run000266.dat
Telescope filename  run000266.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  77   Tue Oct 24 18:08:06 2017 Peter PaulitschHPK_200run000271271110000NoGood
Parameter Value
Alibava filename  run000271.dat
Telescope filename  run000271.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  78   Tue Oct 24 18:08:38 2017 Peter PaulitschHPK_200run000273273110000NoGood
Parameter Value
Alibava filename  run000273.dat
Telescope filename  run000273.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  