  Alibava testbeam at DESY in Oct. 2017 (Dominic, Peter), Page 1 of 7  Not logged in ELOG logo
ID Date Author DUT Subject Run Number Events XYPositionup Cooling Data
  1   Thu Oct 12 10:06:31 2017 Dominic BloechcommonPacklist   NoUnknown

# Testbeam Packliste


### Alibava stuff

* Alibava Mainboard
* Alibava power supply 
* Alibava Modules: IFX_CenterBias, HPK_CenterBias, IFX_baby
* Flatband cable 2x
* Alibava resetbox + Cable
* USB AtoB 2x
* BIAS Cable for BeetleChip
* 2410 SMU + Power + USBtoRS232
* Alibava mounting stuff


### Tools and Stuff

* Labeling machine
* Duct tape
* 2 pairs of wool gloves
* Seitenschneider klein
* USBtoRS232 2x
* Lan cable
* Schiebelehre
* Imbuschlüssel
* Screwdriver set
* Special screwdriver set
* Cutter 2x
* labeling cartridge
* Lemo 16 ns
* Lemo 8 ns 2x
* Lemo 4 ns
* Lemo 2 ns

 

 

### PC and stuff

* DAQ PC + Cables

* Monitor + Cables
* Mouse
* Keyboard

 

### Data Storage
* Toshiba 1TB USB3
* Maxtor 4TB USB3

  2   Mon Oct 16 15:01:21 2017 Dominic BloechcommonPreparations   NoUnknown

### General

* Setup was set-up without problems. Pedestral and Calibration runs with ALIBAVA successfully.

** Warning: Trigger Out signal (busy signal) for the TLU is a TTL signal. Whereas the Trigger In signal can be a NIM signal. Either converting signal or adept in the TLU (we adepted the TLU matrix)

** TLU double triggered -> discriminated TLU signal beforehand 

*  Longterm BIAS Voltage for the IFX CenterBias to -100 V, slow control records IV-behavior in 10 sec steps.

* Security lectures taken

* 3 coincident measurements: 2 PM and the FEI4-Plane are connected to an "and" in the TLU

* Latency of Alibava without FEI4-Plane 133 [a.u] with FEI4 140 [a.u].

** Warning: This is due to the converter from the FEI4 which inverts the signal of the FEI4, this signal is then very noisy and would generate false positive triggers. -> Discriminate -> Long cables and latencies

### Other

* NI-Crate was broken (replaced by DESY)

  75   Tue Oct 24 18:02:47 2017 Peter PaulitschHPK_200run000264264110000NoGood
Parameter Value
Alibava filename  run000264.dat
Telescope filename  run000264.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  76   Tue Oct 24 18:04:09 2017 Peter PaulitschHPK_200run000266266110000NoGood
Parameter Value
Alibava filename  run000266.dat
Telescope filename  run000266.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  77   Tue Oct 24 18:08:06 2017 Peter PaulitschHPK_200run000271271110000NoGood
Parameter Value
Alibava filename  run000271.dat
Telescope filename  run000271.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  78   Tue Oct 24 18:08:38 2017 Peter PaulitschHPK_200run000273273110000NoGood
Parameter Value
Alibava filename  run000273.dat
Telescope filename  run000273.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  79   Tue Oct 24 18:08:57 2017 Peter PaulitschHPK_200run0002752751010000NoGood
Parameter Value
Alibava filename  run000275.dat
Telescope filename  run000275.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  80   Tue Oct 24 18:09:24 2017 Peter PaulitschHPK_200run0002772771010000NoGood
Parameter Value
Alibava filename  run000277.dat
Telescope filename  run000277.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  81   Tue Oct 24 18:09:43 2017 Peter PaulitschHPK_200run000279279110000NoGood
Parameter Value
Alibava filename  run000279.dat
Telescope filename  run000279.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  82   Tue Oct 24 18:10:14 2017 Peter PaulitschHPK_200run000281281110000NoGood
Parameter Value
Alibava filename  run000281.dat
Telescope filename  run000281.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  83   Tue Oct 24 18:10:39 2017 Peter PaulitschHPK_200run0002832831010000NoGood
Parameter Value
Alibava filename  run000283.dat
Telescope filename  run000283.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  84   Tue Oct 24 18:11:13 2017 Peter PaulitschHPK_200run0002852851010000NoGood
Parameter Value
Alibava filename  run000285.dat
Telescope filename  run000285.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  85   Tue Oct 24 18:11:43 2017 Peter PaulitschHPK_200run0002872871010000NoGood
Parameter Value
Alibava filename  run000287.dat
Telescope filename  run000287.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  8   Wed Oct 18 12:12:55 2017 Peter PaulitschIFX_CenterBiasrun000091911010000122.9, 21, -3.3°NoGood
run settings
Parameter Value
Alibava filename  run000091.dat
Telescope filename  run000091.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -165 nA
Sensor temperature 24.6 °C
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 122.9, 21
Region of interest lower part
Trigger frequency  185 Hz
Meas. time 90 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 44.7%

 

  12   Wed Oct 18 13:29:39 2017 Peter PaulitschIFX_CenterBiasrun000102102110000122.9, 23.2, -3.3°NoGood
run settings
Parameter Value
Alibava filename  run000102.dat
Telescope filename  run000102.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -160 nA
Sensor temperature 24.6 °C
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 122.9, 23.8
Region of interest bias line
Trigger frequency  185 Hz
Meas. time 17 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 52.3%

 

  10   Wed Oct 18 12:22:03 2017 Peter PaulitschIFX_CenterBiasrun00009999110000122.9, 23.5, -3.3°NoGood
run settings
Parameter Value
Alibava filename  run000099.dat
Telescope filename  run000099.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -160 nA
Sensor temperature 24.6 °C
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 122.9, 23.5
Region of interest bias line
Trigger frequency  185 Hz
Meas. time 17 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 52.3%

 

  13   Wed Oct 18 13:30:58 2017 Peter PaulitschIFX_CenterBiasrun000104104110000122.9, 23.5, -3.3°NoUnknown
run settings
Parameter Value
Alibava filename  run000104.dat
Telescope filename  run000104.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -160 nA
Sensor temperature 24.6 °C
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 122.9, 23.5
Region of interest bias line
Trigger frequency  200 Hz
Meas. time 15 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 52.3%

 

  14   Wed Oct 18 13:33:05 2017 Peter PaulitschIFX_CenterBiasrun00010610660000122.9, 23.5, -3.3°NoGood
run settings
Parameter Value
Alibava filename  run000106.dat
Telescope filename  run000106.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -160 nA
Sensor temperature 24.6 °C
Latency 140 [a.u.]
Alibava triggers 60000
Telescope triggers 50000
Data synced yes
Table position x/y 122.9, 23.5
Region of interest bias line
Trigger frequency  200 Hz
Meas. time 8 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 53.4%

 

  15   Wed Oct 18 13:34:54 2017 Peter PaulitschIFX_CenterBiasrun000107107110000122.9, 23.5, -3.3°NoGood
run settings
Parameter Value
Alibava filename  run000107.dat
Telescope filename  run000107.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -160 nA
Sensor temperature 24.6 °C
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 122.9, 23.5
Region of interest bias line
Trigger frequency  200 Hz
Meas. time 15 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 53.4%

 

  11   Wed Oct 18 12:28:08 2017 Peter PaulitschIFX_CenterBiasrun00010110110000122.9, 23.8, -3.3°NoGood
run settings
Parameter Value
Alibava filename  run000101.dat
Telescope filename  run000101.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -160 nA
Sensor temperature 24.6 °C
Latency 140 [a.u.]
Alibava triggers 10000
Telescope triggers 14500
Data synced yes
Table position x/y 122.9, 23.8
Region of interest bias line
Trigger frequency  185 Hz
Meas. time 2 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 52.3%

 