  Alibava testbeam at DESY in Oct. 2017 (Dominic, Peter), Page 1 of 7  Not logged in ELOG logo
ID Date Author DUTup Subject Run Number Events XYPosition Cooling Data
  75   Tue Oct 24 18:02:47 2017 Peter PaulitschHPK_200run000264264110000NoGood
Parameter Value
Alibava filename  run000264.dat
Telescope filename  run000264.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature -7
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  76   Tue Oct 24 18:04:09 2017 Peter PaulitschHPK_200run000266266110000NoGood
Parameter Value
Alibava filename  run000266.dat
Telescope filename  run000266.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  77   Tue Oct 24 18:08:06 2017 Peter PaulitschHPK_200run000271271110000NoGood
Parameter Value
Alibava filename  run000271.dat
Telescope filename  run000271.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  78   Tue Oct 24 18:08:38 2017 Peter PaulitschHPK_200run000273273110000NoGood
Parameter Value
Alibava filename  run000273.dat
Telescope filename  run000273.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  79   Tue Oct 24 18:08:57 2017 Peter PaulitschHPK_200run0002752751010000NoGood
Parameter Value
Alibava filename  run000275.dat
Telescope filename  run000275.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  80   Tue Oct 24 18:09:24 2017 Peter PaulitschHPK_200run0002772771010000NoGood
Parameter Value
Alibava filename  run000277.dat
Telescope filename  run000277.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  81   Tue Oct 24 18:09:43 2017 Peter PaulitschHPK_200run000279279110000NoGood
Parameter Value
Alibava filename  run000279.dat
Telescope filename  run000279.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  82   Tue Oct 24 18:10:14 2017 Peter PaulitschHPK_200run000281281110000NoGood
Parameter Value
Alibava filename  run000281.dat
Telescope filename  run000281.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  83   Tue Oct 24 18:10:39 2017 Peter PaulitschHPK_200run0002832831010000NoGood
Parameter Value
Alibava filename  run000283.dat
Telescope filename  run000283.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  84   Tue Oct 24 18:11:13 2017 Peter PaulitschHPK_200run0002852851010000NoGood
Parameter Value
Alibava filename  run000285.dat
Telescope filename  run000285.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -200 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  85   Tue Oct 24 18:11:43 2017 Peter PaulitschHPK_200run0002872871010000NoGood
Parameter Value
Alibava filename  run000287.dat
Telescope filename  run000287.raw
Pedestal filename HEPHY_pedestal_HPK_CB_2.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y  
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling no
Alibava efficiency  
  106   Tue Oct 24 18:43:03 2017 Peter PaulitschHPK_200_1e15run00032832811000076.50, 66.00, 0°YesGood
Parameter Value
Alibava filename  run000328.dat
Telescope filename  run000328.raw
Pedestal filename KIT_pedestal_600V_22102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 76.50, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  107   Tue Oct 24 18:43:57 2017 Peter PaulitschHPK_200_1e15run00033033011000076.50, 66.00, 0°YesGood
Parameter Value
Alibava filename  run000330.dat
Telescope filename  run000330.raw
Pedestal filename KIT_pedestal_600V_22102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 76.50, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  108   Tue Oct 24 18:45:08 2017 Peter PaulitschHPK_200_1e15run00033233211000076.50, 66.00, 0°YesGood
Parameter Value
Alibava filename  run000332.dat
Telescope filename  run000332.raw
Pedestal filename KIT_pedestal_600V_22102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 76.50, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  109   Tue Oct 24 18:46:33 2017 Peter PaulitschHPK_200_1e15run000334334101000076.50, 66.00, 0°YesGood
Parameter Value
Alibava filename  run000334.dat
Telescope filename  run000334.raw
Pedestal filename KIT_pedestal_600V_22102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 76.50, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  110   Tue Oct 24 18:48:15 2017 Peter PaulitschHPK_200_1e15run00033633611000076.50, 66.00, -30°YesGood
Parameter Value
Alibava filename  run000336.dat
Telescope filename  run000336.raw
Pedestal filename KIT_pedestal_600V_22102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 76.50, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  111   Tue Oct 24 18:48:54 2017 Peter PaulitschHPK_200_1e15run00033833811000076.50, 66.00, -30°YesGood
Parameter Value
Alibava filename  run000338.dat
Telescope filename  run000338.raw
Pedestal filename KIT_pedestal_600V_22102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 76.50, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  112   Mon Oct 30 11:36:00 2017 Peter PaulitschHPK_200_1e15run00034034011000075.00, 66.00, -30°YesGood
Parameter Value
Alibava filename  run000340.dat
Telescope filename  run000340.raw
Pedestal filename KIT_pedestal_600V_23102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.00, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  113   Mon Oct 30 11:40:27 2017 Peter PaulitschHPK_200_1e15run000342342101000075.00, 66.00, -30°YesGood
Parameter Value
Alibava filename  run000342.dat
Telescope filename  run000342.raw
Pedestal filename KIT_pedestal_600V_23102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.00, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  114   Mon Oct 30 11:40:56 2017 Peter PaulitschHPK_200_1e15run00034434411000075.00, 66.00, -20°YesGood
Parameter Value
Alibava filename  run000344.dat
Telescope filename  run000344.raw
Pedestal filename KIT_pedestal_600V_23102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 75.00, 66.00
Region of interest bias line
Trigger frequency  135 Hz
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  