Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Alibava testbeam at DESY in Oct. 2017 (Dominic, Peter), Page 1 of 7  Not logged in ELOG logo
ID Date Author DUT Subject Run Numberdown Events XYPosition Cooling Data
  10   Wed Oct 18 12:22:03 2017 Peter PaulitschIFX_CenterBiasrun00009999110000122.9, 23.5, -3.3°NoGood
run settings
Parameter Value
Alibava filename  run000099.dat
Telescope filename  run000099.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -160 nA
Sensor temperature 24.6 °C
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 122.9, 23.5
Region of interest bias line
Trigger frequency  185 Hz
Meas. time 17 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 52.3%

 

  9   Wed Oct 18 12:19:14 2017 Peter PaulitschIFX_CenterBiasrun000093931010000122.9, 26, -3.3°NoGood
run settings
Parameter Value
Alibava filename  run000093.dat
Telescope filename  run000093.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -165 nA
Sensor temperature 24.5 °C
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 122.9, 26
Region of interest all
Trigger frequency  185 Hz
Meas. time 90 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 44.1%

 

  8   Wed Oct 18 12:12:55 2017 Peter PaulitschIFX_CenterBiasrun000091911010000122.9, 21, -3.3°NoGood
run settings
Parameter Value
Alibava filename  run000091.dat
Telescope filename  run000091.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -165 nA
Sensor temperature 24.6 °C
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 122.9, 21
Region of interest lower part
Trigger frequency  185 Hz
Meas. time 90 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 44.7%

 

  7   Wed Oct 18 11:59:30 2017 Peter PaulitschIFX_CenterBiasrun000088881010000122.9, 31, -3.3°NoGood
run settings
Parameter Value
Alibava filename  run000088.dat
Telescope filename  run000088.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -165 nA
Sensor temperature 24.5 °C
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 122.9, 31
Region of interest upper part
Trigger frequency  185 Hz
Meas. time 90 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 45.4%

 

  6   Wed Oct 18 11:48:51 2017 Peter PaulitschIFX_CenterBiasrun000085851010000122.9, 26, -3.3°NoGood
run settings
Parameter Value
Alibava filename  run000085.dat
Telescope filename  run000085.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -165 nA
Sensor temperature 24.5 °C
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 122.9, 26
Region of interest all
Trigger frequency  185 Hz
Meas. time 90 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 44.1%

 

  5   Tue Oct 17 15:15:32 2017 Dominic BloechIFX_CenterBiasrun000083 83260000122.9, 26, -3.3°NoUnknown
run settings
Parameter Value
Alibava filename  run000083.dat
Telescope filename  run000083.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -162 nA
Sensor temperature 22 °C
Latency 140 [a.u.]
Alibava triggers 260000
Telescope triggers  
Data synced yes
Table position x/y 122.9, 26
Region of interest all
Trigger frequency  220 Hz
Meas. time 90 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 44,2%

 

  4   Tue Oct 17 15:13:42 2017 Dominic BloechIFX_CenterBiasrun000081811010000122.9, 26, -3.3°NoGood
run settings
Parameter Value
Alibava filename  run000081.dat
Telescope filename  run000081.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -162 nA
Sensor temperature 22 °C
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 122.9, 26
Region of interest all
Trigger frequency  220 Hz
Meas. time 90 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 44.1%

 

  3   Tue Oct 17 14:46:26 2017 Dominic BloechIFX_CenterBiasrun00008080500000122.9, 26, -3.3°NoUnknown

 

run settings
Parameter Value
Alibava filename  run000080.dat
Telescope filename  run000080.raw
Pedestal filename pedestal_17102017
Bias voltage -100 V
Dark current -162 nA
Sensor temperature 22 °C
Latency 140 [a.u.]
Alibava triggers 500000
Telescope triggers  
Data synced yes
Table position x/y 122.9, 26
Region of interest all
Trigger frequency  220 Hz
Meas. time 90 min
Beam energy 5.6 GeV
Cooling no
Alibava efficiency 43,6%

 

  133   Mon Oct 30 12:04:14 2017 Peter PaulitschIFX_200_1e15run00038938910000076.50, 66.00, 0°YesUnknown
Parameter Value
Alibava filename  run000389.dat
Telescope filename  run000389.raw
Pedestal filename KIT_pedestal_600V_26102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 100000
Telescope triggers 100000
Data synced yes
Table position x/y 76.50, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  132   Mon Oct 30 12:03:27 2017 Peter PaulitschIFX_200_1e15run000388388101000076.50, 66.00, 0°YesGood
Parameter Value
Alibava filename  run000388.dat
Telescope filename  run000388.raw
Pedestal filename KIT_pedestal_600V_26102017.ped
Bias voltage -400 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 76.50, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  131   Mon Oct 30 12:02:54 2017 Peter PaulitschIFX_200_1e15run000387387101000076.50, 66.00, 0°YesGood
Parameter Value
Alibava filename  run000387.dat
Telescope filename  run000387.raw
Pedestal filename KIT_pedestal_600V_26102017.ped
Bias voltage -800 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 76.50, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  130   Mon Oct 30 12:02:05 2017 Peter PaulitschIFX_200_1e15run000384384101000076.50, 66.00, 0°YesGood
Parameter Value
Alibava filename  run000384.dat
Telescope filename  run000384.raw
Pedestal filename KIT_pedestal_600V_26102017.ped
Bias voltage -500 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 76.50, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  129   Mon Oct 30 12:00:43 2017 Peter PaulitschIFX_200_1e15run000383383270999976.50, 66.00, 0°YesGood
Parameter Value
Alibava filename  run000383.dat
Telescope filename  run000383.raw
Pedestal filename KIT_pedestal_600V_26102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 2709999
Telescope triggers 2709950
Data synced yes
Table position x/y 76.50, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  128   Mon Oct 30 11:55:04 2017 Peter PaulitschIFX_200_1e15run00037937915000076.50, 66.00, 0°YesGood
Parameter Value
Alibava filename  run000379.dat
Telescope filename  run000379.raw
Pedestal filename KIT_pedestal_600V_26102017.ped
Bias voltage -400 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 150000
Telescope triggers 150000
Data synced yes
Table position x/y 76.50, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  127   Mon Oct 30 11:54:14 2017 Peter PaulitschIFX_200_1e15run000377377101000076.50, 66.00, -10°YesGood
Parameter Value
Alibava filename  run000377.dat
Telescope filename  run000377.raw
Pedestal filename KIT_pedestal_600V_26102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 76.50, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency 33.7%
  126   Mon Oct 30 11:53:33 2017 Peter PaulitschIFX_200_1e15run000375375101000075.00, 66.00, -20°YesGood
Parameter Value
Alibava filename  run000375.dat
Telescope filename  run000375.raw
Pedestal filename KIT_pedestal_600V_26102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.00, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  125   Mon Oct 30 11:52:26 2017 Peter PaulitschIFX_200_1e15run000373373101000075.00, 66.00, -30°YesGood
Parameter Value
Alibava filename  run000373.dat
Telescope filename  run000373.raw
Pedestal filename KIT_pedestal_600V_26102017.ped
Bias voltage -600 V
Dark current 100 uA
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 1010000
Telescope triggers 1000000
Data synced yes
Table position x/y 75.00, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  124   Mon Oct 30 11:51:46 2017 Peter PaulitschHPK_200_1e15run00036836811000076.50, 66.00, -30°YesGood
Parameter Value
Alibava filename  run000368.dat
Telescope filename  run000368.raw
Pedestal filename KIT_pedestal_600V_26102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 110000
Telescope triggers 100000
Data synced yes
Table position x/y 76.50, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  123   Mon Oct 30 11:50:22 2017 Peter PaulitschHPK_200_1e15run00036536551000076.50, 66.00, 4°YesGood
Parameter Value
Alibava filename  run000365.dat
Telescope filename  run000365.raw
Pedestal filename KIT_pedestal_600V_26102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 510000
Telescope triggers 500000
Data synced yes
Table position x/y 76.50, 66.00
Region of interest bias line
Trigger frequency   
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
  122   Mon Oct 30 11:48:12 2017 Peter PaulitschHPK_200_1e15run00036436425000076.50, 66.00, 5°YesGood
Parameter Value
Alibava filename  run000364.dat
Telescope filename  run000364.raw
Pedestal filename KIT_pedestal_600V_23102017.ped
Bias voltage -600 V
Dark current  
Sensor temperature  
Latency 140 [a.u.]
Alibava triggers 250000
Telescope triggers 250000
Data synced yes
Table position x/y 76.50, 66.00
Region of interest bias line
Trigger frequency  135 Hz
Meas. time  
Beam energy 5.6 GeV
Cooling yes
Alibava efficiency  
ELOG V3.1.5-fc6679b