Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Alibava/Mapsa testbeam at DESY in April 2017 (Axel, Grossi), Page 7 of 7  Not logged in ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
Entry  Thu Apr 13 21:23:11 2017, Axel Koenig, ALiBaVa (IFX), run_018_IFX_CB_120V.dat, 018, 175000, 109, 4.5, 240, No, Unknown 
Remarks: Telescope run 533. Bias scan 120 V.




Parameter
Value


Alibava run
run_018_IFX_CB_120V.dat


Entry  Fri Apr 21 08:15:03 2017, Axel Koenig, ALiBaVa (IFX), run_018_Irrad_500V.dat, 018, 200000, 96, 64, 360, No, Unknown 
Remarks: Telescope run 650. Bias voltage -500V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared
to other DUTs). Telescope geometry identical to double irrad module.

Backside Biasing!
Entry  Mon Apr 17 10:05:57 2017, Axel Koenig, ALiBaVa (IFX), run_019_Baby_110V.dat, 019, 112000, 102.5, 22.5, 240, No, Unknown 
Remarks: Telescope run 596. Bias scan 110 V.

Telescope chiller turned off (could be the root cause of runs crashing).




Parameter
Entry  Fri Apr 21 08:38:17 2017, Axel Koenig, ALiBaVa (IFX), run_019_Irrad_500V.dat, 019, 200000, 96, 64, 360, No, Unknown 
Remarks: Telescope run 651. Bias voltage -500V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared
to other DUTs). Telescope geometry identical to double irrad module.

Backside Biasing!
Entry  Mon Apr 17 10:36:22 2017, Axel Koenig, ALiBaVa (IFX), run_020_Baby_120V.dat, 020, 112000, 102.5, 22.5, 240, No, Unknown 
Remarks: Telescope run 597. Bias scan 120 V.

Telescope chiller turned off (could be the root cause of runs crashing).




Parameter
Entry  Fri Apr 14 08:59:26 2017, Axel Koenig, ALiBaVa (IFX), run_020_IFX_CB_100V.dat, 020, 190000, 109, 4.5, 240, No, Crap 
Remarks: Telescope run 535. Bias scan 100 V. Run crashed over night. Telescope sync only up to event 190000 (planned 2500000 events).




Parameter
Value


Alibava run
run_020_IFX_CB_100V.dat


Entry  Fri Apr 21 08:57:30 2017, Axel Koenig, ALiBaVa (IFX), run_020_Irrad_500V.dat, 020, 200000, 96, 64, 360, No, Unknown 
Remarks: Telescope run 652. Bias voltage -500V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared
to other DUTs). Telescope geometry identical to double irrad module.

Backside Biasing!
Entry  Mon Apr 17 11:04:40 2017, Axel Koenig, ALiBaVa (IFX), run_021_Baby_130V.dat, 021, 112000, 102.5, 22.5, 240, No, Unknown 
Remarks: Telescope run 598. Bias scan 130 V.

Telescope chiller turned off (could be the root cause of runs crashing).




Parameter
Entry  Fri Apr 21 09:14:45 2017, Axel Koenig, ALiBaVa (IFX), run_021_Irrad_500V.dat, 021, 200000, 96, 64, 360, No, Unknown 
Remarks: Telescope run 653. Bias voltage -500V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared
to other DUTs). Telescope geometry identical to double irrad module.

Backside Biasing!
Entry  Mon Apr 17 11:34:55 2017, Axel Koenig, ALiBaVa (IFX), run_022_Baby_140V.dat, 022, 112000, 102.5, 22.5, 240, No, Unknown 
Remarks: Telescope run 599. Bias scan 140 V.

Telescope chiller turned off (could be the root cause of runs crashing).




Parameter
Entry  Fri Apr 14 13:06:30 2017, Axel Koenig, ALiBaVa (IFX), run_022_IFX_CB_100V.dat, 022, 500000, 109, 10.5, 240, No, Unknown 
Remarks: Telescope run 545. Bias voltage 100 V. Beam position on only one chip.




Parameter
Value


Alibava run
run_022_IFX_CB_100V.dat


Entry  Mon Apr 17 12:06:11 2017, Axel Koenig, ALiBaVa (IFX), run_023_Baby_150V.dat, 023, 112000, 102.5, 22.5, 240, No, Unknown 
Remarks: Telescope run 600. Bias scan 150 V.

Telescope chiller turned off (could be the root cause of runs crashing).




Parameter
Entry  Fri Apr 14 14:49:09 2017, Axel Koenig, ALiBaVa (IFX), run_023_IFX_CB_100V.dat, 023, 385000, 109, 0, 240, No, Crap 
Remarks: Telescope run 546. Bias voltage 100 V. Beam position on only one chip. Run destroyed. Intended trigger count 500k




Parameter
Value


Alibava run
run_023_IFX_CB_100V.dat


Entry  Fri Apr 14 09:25:09 2017, Axel Koenig, ALiBaVa (IFX), run_024_IFX_CB_140V.dat, 024, 175000, 109, 4.5, 240, No, Unknown 
3Remarks: Telescope run 547. Bias scan 140 V.




Parameter
Value


Alibava run
run_024_IFX_CB_140V.dat


Entry  Fri Apr 14 17:22:52 2017, Axel Koenig, ALiBaVa (IFX), run_025_IFX_CB_150V.dat, 025, 175000, 109, 4.5, 240, No, Unknown 
3Remarks: Telescope run 548. Bias scan 150 V.




Parameter
Value


Alibava run
run_025_IFX_CB_150V.dat


Entry  Fri Apr 14 18:22:58 2017, Axel Koenig, ALiBaVa (IFX), run_026_IFX_CB_100V.dat, 026, 350000, 109, 4.5, 230, No, Unknown 
Remarks: Telescope run 549. Angle shift 230 deg.




Parameter
Value


Alibava run
run_026_IFX_CB_100V.dat


Entry  Fri Apr 14 19:43:13 2017, Axel Koenig, ALiBaVa (IFX), run_027_IFX_CB_100V.dat, 027, 350000, 109, 4.5, 250, No, Unknown 
Remarks: Telescope run 550. Angle shift 250 deg.




Parameter
Value


Alibava run
run_027_IFX_CB_100V.dat


Entry  Fri Apr 14 21:11:18 2017, Axel Koenig, ALiBaVa (IFX), run_028_IFX_CB_100V.dat, 028, 3000000, 109, 4.5, 240, No, Crap 
Remarks: Telescope run 551. Longrun over night. Run crashed. Events only up to 2288000 valid.




Parameter
Value


Alibava run
run_028_IFX_CB_100V.dat


Entry  Sat Apr 15 09:57:51 2017, Axel Koenig, ALiBaVa (IFX), run_029_IFX_CB_130V.dat, 029, 175000, 109, 4.5, 240, No, Unknown 
3Remarks: Telescope run 557. Bias scan 130 V.




Parameter
Value


Alibava run
run_029_IFX_CB_130V.dat


Entry  Sat Apr 15 12:12:00 2017, Axel Koenig, ALiBaVa (IFX), run_030_IFX_CB_100V.dat, 030, 1000000, 109, 4.5, 240, No, Unknown 
3Remarks: Telescope run 558. Bias scan 100 V. Telescope chiller turned off. Could be the root cause of crashing runs.




Parameter
Value


Alibava run
run_030_IFX_CB_100V.dat


ELOG V3.1.5-fc6679b