Entry  Wed Apr 19 20:55:36 2017, Axel Koenig, ALiBaVa (IFX), run_003_Irrad_300V.dat, 003, 300000, 96, 64, 360, No, Unknown 
Remarks: Telescope run 632. Bias scan -300V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared
to other DUTs). Telescope geometry identical to double irrad module.

Backside Biasing!
Entry  Wed Apr 12 22:34:18 2017, Axel König, ALiBaVa (IFX), run_002_IFX_CB_100V.dat, 002, 100000, 109, 0.5, 240, No, Unknown 
Remarks: Beam position on only one chip.




Parameter
Value


Alibava run
Entry  Sat Apr 15 17:38:58 2017, Axel Koenig, ALiBaVa (IFX), run_002_Baby_100V.dat, 002, 250000, 102.5, 12.5, 240, No, Unknown 
Remarks: Telescope run 563. Telescope chiller turned off (could be the root cause of runs crashing).




Parameter
Value


Alibava run
run_002_Baby_100V.dat


Entry  Mon Apr 17 16:36:56 2017, Axel Koenig, ALiBaVa (IFX), run_002_HPK_CB_200V.dat, 002, 450000, 107, 5.8, 240, No, Unknown 
Remarks: Telescope run 605. Bias scan 200 V. Only one chip.

Telescope chiller turned off (could be the root cause of runs crashing).




Parameter
Entry  Tue Apr 18 18:48:27 2017, Axel Koenig, ALiBaVa (IFX), run_002_double_irrad_100V.dat, 002, 700000, 94, 1, 240, No, Unknown 
Remarks: Telescope run 623. 1nd chip only. Central position.

Telescope chiller turned on!




Parameter
Entry  Wed Apr 19 19:27:38 2017, Axel Koenig, ALiBaVa (IFX), run_002_Irrad_200V.dat, 002, 400000, 96, 64, 360, No, Unknown 
Remarks: Telescope run 630. Bias scan -200V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared
to other DUTs). Telescope geometry identical to double irrad module.

Backside Biasing!
Entry  Wed Apr 12 21:06:44 2017, Axel König, ALiBaVa (IFX), run_001_IFX_CB_100V.dat, 001, 200000, 109, 4.5, 240, No, Unknown 11.png46.png
First run for alibava modules with Sensor IFX_CB.

Beam energy = 5.6 GeV

Telescope threshold = 6
Entry  Thu Apr 13 10:03:29 2017, Axel König, ALiBaVa (IFX), run_001_IFX_CB_100V.dat, 001, 200000, 109, 4.5, 240, No, Unknown 
Remarks: Telescope run 496. Bias voltage 100 V. First run at DESY TB.




Parameter
Value


Alibava run
run_001_IFX_CB_100V.dat


Entry  Sat Apr 15 16:52:06 2017, Axel Koenig, ALiBaVa (IFX), run_001_Baby_100V.dat, 001, 250000, 102.5, 22.5, 240, No, Unknown 
Remarks: Telescope run 562. Telescope chiller turned off (could be the root cause of runs crashing).

Position: 102.5, 22.5, 240 (should be the center of the sensor).




Parameter
Entry  Mon Apr 17 13:30:01 2017, Axel Koenig, ALiBaVa (IFX), run_001_HPK_CB_200V.dat, 001, 450000, 107, 0, 240, No, Unknown 
Remarks: Telescope run 604. Bias scan 200 V. Only one chip.

Telescope chiller turned off (could be the root cause of runs crashing).




Parameter
Entry  Tue Apr 18 18:19:33 2017, Axel Koenig, ALiBaVa (IFX), run_001_double_irrad_100V.dat, 001, 350000, 111, 1, 240, No, Unknown 
Remarks: Telescope run 620. 2nd chip only. Central position.

Telescope chiller turned on!




Parameter
Entry  Wed Apr 19 17:31:43 2017, Axel Koenig, ALiBaVa (IFX), run_001_Irrad_100V.dat, 001, 400000, 96, 64, 360, No, Unknown 
Remarks: Telescope run 628. Bias scan -100V, central position of sensor (DUT parallel to telescope planes at 360 deg due to different fixation compared
to other DUTs). Telescope geometry identical to double irrad module.

Backside Biasing!
Entry  Wed Apr 12 21:55:13 2017, Axel König, common, pulse shape , , , , No, Unknown 21.png
pulse shape looks good for latency 132. This value is now taken by default for all runs unless otherwise stated.
Entry  Wed Apr 12 21:56:48 2017, Axel König, common, Kazu beetle settings, , , , No, Unknown 
Beetle setting for a better defined pulse shape. These parameters were found by kazu, a beetle developer at lhcb.

CompCtrl=9
Ibuf=10
Entry  Fri Apr 14 14:21:35 2017, Axel Koenig, common, Run summary IFX_CB , , , , No, Unknown 



Alibava
run
Telescope run
File existence check
Run type
Triggers
Remarks


Entry  Sat Apr 15 16:55:19 2017, Axel Koenig, common, Chiller turned off!, , , , No, Unknown 
The chiller has been turned off beginning of run_30_IFX_CB_100V.dat.

Set temperature was 15 C. Now it should settle at 20 +- 1 C (room temperature).




 
 


Entry  Mon Apr 17 10:14:15 2017, Axel Koenig, common, Run summary Baby, , , , No, Unknown 



Alibava
run
Telescope run
File existence check
Run type
Triggers
Remarks


Entry  Mon Apr 17 17:25:24 2017, Axel Koenig, common, Telescope geometry ALiBaVa, , , , No, Unknown IMG_1522.JPGbeam.pdfbeam1.pdfbeam2.pdf
The plane distances are measured at the center of the planes.

The distance of the DUT to the neighbouring planes is measured from the position of the sensor to the center of the planes.




 
 


Entry  Tue Apr 18 17:55:19 2017, Axel Koenig, common, Run summary HPK_CB, , , , No, Unknown 



Alibava
run
Telescope run
File existence check
Run type
Triggers
Remarks


Entry  Tue Apr 18 17:56:37 2017, Axel Koenig, common, Run summary HPK_CB, , , , No, Unknown 



Alibava
run
Telescope run
File existence check
Run type
Triggers
Remarks


ELOG V3.1.5-fc6679b