Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  Alibava/Mapsa testbeam at DESY in April 2017 (Axel, Grossi), Page 3 of 7  Not logged in ELOG logo
ID Date Author Project Subject Run Number Events XYPositionup Cooling Data
  57   Fri Apr 14 00:40:23 2017 Johannes GrossmannMaPSATeleskope Correlation51500000NoUnknown

Telescope 1294

Threshold 90 

Mapsa CLK Delay 24 ns

  58   Fri Apr 14 01:33:35 2017 Johannes GrossmannMaPSATeleskope Correlation522500000NoUnknown

Telescope 1296

Threshold 90 

Mapsa CLK Delay 0 

  62   Fri Apr 14 12:26:00 2017 Johannes GrossmannMaPSAAlignment Check602500000NoUnknown

Telescope 1312

Threshold 80

Mapsa CLK Delay 0

Carbon fiber  broken at 2:20 AM. Alignement check.

  63   Fri Apr 14 12:48:44 2017 Johannes GrossmannMaPSAAlignment Check612500000NoUnknown

Telescope 1314

Threshold 80

Mapsa CLK Delay 0

Reference Plane Lost aber Anfang Gut

  64   Fri Apr 14 12:58:08 2017 Johannes GrossmannMaPSAAlignment Check642500000NoUnknown

Telescope 1316

Threshold 80

Mapsa CLK Delay 0

Reference Plane Lost aber Anfang Gut

  66   Fri Apr 14 13:21:07 2017 Johannes GrossmannMaPSAAlignment Check662500000NoUnknown

Telescope 1318

Threshold 100

Mapsa CLK Delay 0

Reference Plane Lost aber Anfang Gut

  91   Sun Apr 16 22:42:51 2017 Johannes GrossmannMaPSAHV_Scan38700NoUnknown

Changed HV from 100V to 80 V

22:41 16.4.2017

  97   Mon Apr 17 10:10:33 2017 Johannes GrossmannMaPSAHV_Scan38700NoUnknown

Changed HV from 80 V to 60 V

Not in condition data applied in the settings

10:08 17.4.2017 

  103   Mon Apr 17 12:26:33 2017 Johannes GrossmannMaPSAHV_Scan45600NoUnknown

Changed HV from 60 V to 120 V

12:24 17.4.2017 

  110   Mon Apr 17 17:55:55 2017 Johannes GrossmannMaPSAHV_Scan48800NoUnknown

Changed HV from 120 V to 90 V

17:53 17.4.2017

  116   Mon Apr 17 23:50:59 2017 Johannes GrossmannMaPSAHV_Scan52200NoUnknown

Changed HV from 90 V to 80 V

Kann ich wegwerfen!

23:49 17.4.2017

  117   Mon Apr 17 23:52:47 2017 Johannes GrossmannMaPSAHV_Scan52300NoUnknown

Changed HV 80 V

23:50 17.4.2017

  120   Tue Apr 18 16:16:59 2017 Johannes GrossmannMaPSAStd Settings60400NoUnknown

Changed HV 100 V Threshold 75

16:14 17.4.2017

Telescope Runnumber 1855

  126   Tue Apr 18 21:55:44 2017 Johannes GrossmannMaPSARotation63500NoUnknown

HV 100 V Threshold 75 Winkel 15

16:14 17.4.2017

Telescope Runnumber 1887

  135   Thu Apr 20 10:07:30 2017 Johannes GrossmannMaPSARotation63500NoUnknown

HV 100 V Threshold 75 Winkel 25

16:14 17.4.2017

Telescope Runnumber 1887

  77   Sat Apr 15 17:38:58 2017 Axel KoenigALiBaVa (IFX)run_002_Baby_100V.dat002250000102.5, 12.5, 240NoUnknown

Remarks: Telescope run 563. Telescope chiller turned off (could be the root cause of runs crashing).

Parameter Value
Alibava run run_002_Baby_100V.dat
Telescope run 563
Triggers 250000
Alibava trigger eff. ~93%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100
Latency 132
Table x 102.5 mm
Table z 12.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  80   Sat Apr 15 20:12:41 2017 Axel KoenigALiBaVa (IFX)run_005_Baby_100V.dat005250000102.5, 22.5, 230NoUnknown

Remarks: Telescope run 568. Telescope chiller turned off (could be the root cause of runs crashing).

Parameter Value
Alibava run run_005_Baby_100V.dat
Telescope run 568
Triggers 250000
Alibava trigger eff. ~93%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100
Latency 132
Table x 102.5 mm
Table z 22.5 mm
Tabe rot

230 deg

  94   Mon Apr 17 09:04:02 2017 Axel KoenigALiBaVa (IFX)run_006_Baby_100V.dat006k.a.102.5, 22.5, 230NoUnknown

Remarks: Telescope run 570. Telescope chiller turned off (could be the root cause of runs crashing).

Forgot ro record data in elog.

Parameter Value
Alibava run run_006_Baby_100V.dat
Telescope run 570
Triggers k.a.
Alibava trigger eff. ~93%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100
Latency 132
Table x 102.5 mm
Table z 22.5 mm
Tabe rot

230 deg

  75   Sat Apr 15 16:52:06 2017 Axel KoenigALiBaVa (IFX)run_001_Baby_100V.dat001250000102.5, 22.5, 240NoUnknown

Remarks: Telescope run 562. Telescope chiller turned off (could be the root cause of runs crashing).

Position: 102.5, 22.5, 240 (should be the center of the sensor).

Parameter Value
Alibava run run_001_Baby_100V.dat
Telescope run 562
Triggers 250000
Alibava trigger eff. ~93%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -100
Latency 132
Table x 102.5 mm
Table z 22.5 mm
Tabe rot

240 deg (parallel to tele. planes)

  81   Sat Apr 15 21:18:26 2017 Axel KoenigALiBaVa (IFX)run_007_Baby_10V.dat007450000102.5, 22.5, 240NoCrap

Remarks: Telescope run 579. Bias scan 10 V. run crashed. Data vaild up to 274915.

Telescope chiller turned off (could be the root cause of runs crashing).

Parameter Value
Alibava run run_007_Baby_10V.dat
Telescope run 579
Triggers 450000
Alibava trigger eff. ~24%
Beam energy 5.6 GeV
Telescope threshold 6
Bias voltage -10
Latency 132
Table x 102.5 mm
Table z 22.5 mm
Tabe rot

240 deg

ELOG V3.1.5-fc6679b