Entry  Wed May 7 16:43:37 2014, Benedikt Würkner, Belle II, source, L3 module, No 4 of 6 room temperature measurements using Sr90 Source (multi6) 10x
Sr90 Radioactive Source
No cooling
Module position: -5:-30(bottom left)
Entry  Wed May 7 17:33:21 2014, Benedikt Würkner, Belle II, source, L3 module, No 5 of 6 room temperature measurements using Sr90 Source (multi6) 10x
Sr90 Radioactive Source
No cooling
Module position: -32:-30(bottom center)
Entry  Wed May 7 18:20:36 2014, Benedikt Würkner, Belle II, source, L3 module, No 6 of 6 room temperature measurements using Sr90 Source (multi6) 10x
Sr90 Radioactive Source
No cooling
Module position: -57:-30(bottom right)
Entry  Thu May 8 16:51:03 2014, Benedikt Würkner, Belle II, source, L3 module, No 1 of 6 room temperature measurements using Sr90 Source (single) 10x
Sr90 Radioactive Source
No cooling
Module position: 0:0(top left)
Entry  Thu May 8 16:51:57 2014, Benedikt Würkner, Belle II, source, L3 module, No 2 of 6 room temperature measurements using Sr90 Source (single) 
Failed with Error: "***ERROR*** Init NECO failed,  Return code: -32761"
Restarted and it works again
Sr90 Radioactive Source
Entry  Fri May 9 15:12:44 2014, Benedikt Würkner, Belle II, source, L3 module, No 2 of 6 room temperature measurements using Sr90 Source (single) 10x
Sr90 Radioactive Source
No cooling
Module position: -27:0(top center)
Entry  Fri May 9 16:44:41 2014, Benedikt Würkner, Belle II, source, L3 module, No 3 of 6 room temperature measurements using Sr90 Source (single) 10x
Sr90 Radioactive Source
No cooling
Module position: -54:0(top center)
Entry  Fri May 16 11:37:05 2014, Benedikt Würkner, Belle II, source, L3 module, No 4 of 6 room temperature measurements using Sr90 Source (single) 10x
Sr90 Radioactive Source
No cooling
Module position: 0:-10(bottom left)
Entry  Fri May 16 11:38:44 2014, Benedikt Würkner, Belle II, source, L3 module, No 5 of 6 room temperature measurements using Sr90 Source (single) 10x
Sr90 Radioactive Source
No cooling
Module position: -27:-10(bottom center)
Entry  Fri May 16 11:40:29 2014, Benedikt Würkner, Belle II, source, L3 module, No 6 of 6 room temperature measurements using Sr90 Source (single) 10x
Sr90 Radioactive Source
No cooling
Module position: -54:-10(bottom right)
Entry  Thu Jun 5 10:33:46 2014, Benedikt Würkner, Belle II, source, Silc Module, Silc Angle Measurement 1° 
Measured the Silc 03/10 Module using the Sr90 Source to have a comparison for the Eta-Distribution at different angles. 
Data can be found on heros in: /home/medialib/LAB_Silc_Angle. 
Plots made with TuxOA for all different regions can be found in /home/users/bwuerkner/plots/. 
Entry  Thu Jun 5 10:34:06 2014, Benedikt Würkner, Belle II, source, Silc Module, Silc Angle Measurement 4° 
Measured the Silc 03/10 Module using the Sr90 Source to have a comparison for the Eta-Distribution at different angles. 
Data can be found on heros in: /home/medialib/LAB_Silc_Angle. 
Plots made with TuxOA for all different regions can be found in /home/users/bwuerkner/plots/. 
Entry  Thu Jun 5 10:34:29 2014, Benedikt Würkner, Belle II, source, Silc Module, Silc Angle Measurement 7° 
Measured the Silc 03/10 Module using the Sr90 Source to have a comparison for the Eta-Distribution at different angles. 
Data can be found on heros in: /home/medialib/LAB_Silc_Angle. 
Plots made with TuxOA for all different regions can be found in /home/users/bwuerkner/plots/. 
Entry  Thu Jun 5 10:34:45 2014, Benedikt Würkner, Belle II, source, Silc Module, Silc Angle Measurement 10° 
Measured the Silc 03/10 Module using the Sr90 Source to have a comparison for the Eta-Distribution at different angles. 
Data can be found on heros in: /home/medialib/LAB_Silc_Angle. 
Plots made with TuxOA for all different regions can be found in /home/users/bwuerkner/plots/. 
Entry  Tue May 19 09:31:50 2015, Hao Yin, , , , Noise Test ITA 
Everything works except L3 p-side.

The config file is shown in the following:

### Original Configuration File Name: /home/katsuro/tuxdaq_devel/config/delay_scan.latency_scan.cfg ###
Entry  Tue May 19 10:08:53 2015, Hao Yin, , , , FADC system setup success 
3 FADC. All Channel/APV25 running (except L3 n first and last -> not connected (bonding))

n-side: all connectors

p-side: 0x01: 1, 2, 4 and 0x02, 1 with L3 p and L4 p (Telescope)
Entry  Tue May 19 10:57:19 2015, Hao Yin, Belle II, system, FIR, FIR filter 
first fir filter run:

# 1:[0x[FADC ID] in hex], 2:[APV25 ChannelNr], 3-10:[fir coef in float]

0x1,0,1.13520608876,-0.0660414994664,-0.0344046528212,-0.0160940592489,-0.0188049576486,-0.00405635272718,0.0022422085805,0.0019532245698
Entry  Tue May 19 11:01:29 2015, Hao Yin, Belle II, system, Pedestal, PedestalRun 16x
FIRRun001

Baseline measurement without injections, 50000 event,

room temperature.
Entry  Tue May 19 13:23:16 2015, Hao Yin, Belle II, system, Calibration, CalibrationRun001 
PedestalRun001, FIRRun001,

room temperature,

no noise injection
Entry  Tue May 19 13:42:04 2015, Hao Yin, , , , L6 Noise inJection Setup P1000702.JPGP1000700.JPGP1000699.JPGP1000703.JPGP1000707.JPG
Test Nr. 1:

RLC between DockBox and Hybrid (both side).

Preliminary Test on L6, but all other sensors are connected.