Home CMS Production Clean room MedAustron HEPHY testbeams old
testbeam-RD50-DESY-Apr2024 testbeam-RD50-DESY-Jul2023 testbeam-RD50-CERN-Oct2022 testbeam-DESY-Oct2017 testbeam-DESY-April2017 testbeam-SPS2015 testbeam-SPS2014 testbeam-DESY14 testbeam-SPS12 testbeam-SPS11 testbeam-SPS10 testbeam-SPS09 testbeam-SPS08 LP-TPC
  RD50 MPW3 Beamtest at CERN SPS, all entries  Not logged in ELOG logo
ID Date Author Subject DUT Threshold RefDetectors Run Number Events XYPosition Data Text Attachments
  77   Wed Oct 26 08:00:03 2022 RD50 Generic UserEnd of SuccessHEPHY_DUT11.2FEi4 | Mimosa949-977 111mm/77.75mmGoodGreetings from Berhard, Christian and Patrick
from CERN H6B ;)

 
  
  76   Wed Oct 26 07:58:43 2022 RD50 Generic UserLong night runsHEPHY_DUT11.2FEi4 | Mimosa949-977 111mm/77.75mmGoodwith new Firmware, streched t0   
  75   Tue Oct 25 16:50:02 2022 RD50 Generic UserSyncable Data RunHEPHY_DUT11.2FEi4 | Mimosa941-948 111mm/77.75mmGoodwith new Firmware, streched t0   
  74   Tue Oct 25 11:53:44 2022 RD50 Generic UserSyncable Data RunHEPHY_DUT11.2FEi4 | Mimosa940 111mm/77.75mmGoodwith new Firmware, streched t0, 10min run
for loading into corry
  
  73   Tue Oct 25 11:44:25 2022 RD50 Generic UserSyncable Data RunHEPHY_DUT11.2FEi4 | Mimosa939 111mm/77.75mmGoodwith new Firmware, streched t0, short run   
  72   Tue Oct 25 11:44:20 2022 RD50 Generic UserSyncable Data RunHEPHY_DUT11.2FEi4 | Mimosa938 111mm/77.75mmGoodwith new Firmware, streched t0, short run   
  71   Tue Oct 25 11:43:45 2022 RD50 Generic UserSyncable Data RunHEPHY_DUT11.2FEi4 | Mimosa937 111mm/77.75mmGoodwith new Firmware, streched t0, short run   
  70   Tue Oct 25 11:43:01 2022 RD50 Generic UserNight runs with 1min noiseHEPHY_DUT11.2FEi4 | Mimosa925-936 111mm/77.75mmCraptesting t0   
  69   Tue Oct 25 11:42:29 2022 RD50 Generic UserNight runs with 1min noiseHEPHY_DUT11.2FEi4 | Mimosa910-925 111mm/77.75mmUnknownshort runs for t0 tests and 30s noise test   
  68   Tue Oct 25 01:29:03 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa906-909 111mm/77.75mmUnknownshort runs for t0 tests and 30s noise test   
  67   Tue Oct 25 01:07:36 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa905 111mm/77.75mmUnknownshort run for t0 tests, start during spill   
  66   Tue Oct 25 01:07:26 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa904 111mm/77.75mmUnknownshort run for t0 tests   
  65   Tue Oct 25 01:04:20 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa900-903 111mm/77.75mmUnknownshort run for t0 tests   
  64   Tue Oct 25 00:15:19 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa899 111mm/77.75mmUnknownshort run for t0 tests   
  63   Tue Oct 25 00:15:09 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa898 111mm/77.75mmUnknownshort run for t0 tests   
  62   Mon Oct 24 23:38:51 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa897 111mm/77.75mmUnknownshort run with new 1us UDP query again...   
  61   Mon Oct 24 23:38:21 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa896 111mm/77.75mmUnknownshort run with old 100us UDP query   
  60   Mon Oct 24 23:37:48 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa884-895 111mm/77.75mmCrapstart/stop for testing t0   
  59   Mon Oct 24 22:39:44 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa883 111mm/77.75mmUnknownshortrun for checking after powercycling
ZYNC
  
  58   Mon Oct 24 22:39:23 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa874-882 111mm/77.75mmUnknown    
  57   Mon Oct 24 18:34:25 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa873 111mm/77.75mmCrappressed start too early   
  56   Mon Oct 24 18:33:15 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa872 111mm/77.75mmGoodshort run for t0 check   
  55   Mon Oct 24 18:10:56 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa871 111mm/77.75mmCrapno beam, checking....   
  54   Mon Oct 24 18:01:34 2022 RD50 Generic UserSyncable data runHEPHY_DUT21.2FEi4 | Mimosa870 111mm/77.75mmGoodno t0, screw in hephy 1 again   
  53   Mon Oct 24 18:00:40 2022 RD50 Generic UserSyncable data runHEPHY_DUT21.2FEi4 | Mimosa869 111mm/77.75mmGoodshort testrun for bernhard if he can see
t0

DUT exchange, IFIC_DUT has t0 connected
  
  52   Mon Oct 24 17:29:14 2022 RD50 Generic UserSyncable data runIFIC_DUT11.2FEi4 | Mimosa868 111mm/77.75mmGood 

 
  
  51   Mon Oct 24 17:29:07 2022 RD50 Generic UserSyncable data runIFIC_DUT11.2FEi4 | Mimosa867 111mm/77.75mmGood 

 
  
  50   Mon Oct 24 17:29:02 2022 RD50 Generic UserSyncable data runIFIC_DUT11.2FEi4 | Mimosa866 111mm/77.75mmGood 

 
  
  49   Mon Oct 24 17:28:53 2022 RD50 Generic UserSyncable data runIFIC_DUT11.2FEi4 | Mimosa865 111mm/77.75mmGood 

 
  
  48   Mon Oct 24 15:19:00 2022 RD50 Generic UserSyncable data runIFIC_DUT11.2FEi4 | Mimosa864 111mm/77.75mmGoodRun with new DUT

 
  
  47   Mon Oct 24 15:18:26 2022 RD50 Generic UserSyncable data runIFIC_DUT11.2FEi4 | Mimosa863 111mm/77.75mmCrapEUDAQ crashed

 
  
  46   Mon Oct 24 15:10:11 2022 RD50 Generic UserSyncable data runIFIC_DUT21.2FEi4 | Mimosa858-862 111mm/77.75mmGoodAccess to change DUT after 862

 
  
  45   Mon Oct 24 11:50:11 2022 RD50 Generic UserSyncable data runIFIC_DUT21.2FEi4 | Mimosa857 111mm/77.75mmGoodaccess ended for 136 beam again for run
starting 857

 
  
  44   Mon Oct 24 11:06:01 2022 RD50 Generic UserSyncable data runIFIC_DUT21.2FEi4 | Mimosa856 111mm/77.75mmGoodaccess again for 136

 
  
  43   Mon Oct 24 10:56:49 2022 RD50 Generic UserSyncable data runIFIC_DUT21.2FEi4 | Mimosa856 111mm/77.75mmGoodaccess ended at 10:56

beam again for run 856 onwards

 
  
  42   Mon Oct 24 09:26:01 2022 RD50 Generic UserSyncable data runIFIC_DUT21.2FEi4 | Mimosa826-852 111mm/77.75mmGoodarrived at 9:24

overnight the automate script has
created 27 runs
  
  41   Sun Oct 23 18:22:38 2022 RD50 Generic UserSyncable data runIFIC_DUT21.2FEi4 | Mimosa825 111mm/77.75mmGoodDUT changed to Ricardo1

-> maybe re-align telescope
  
  40   Sun Oct 23 18:22:23 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa824 111mm/77.75mmGood    
  39   Sun Oct 23 18:22:13 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa823 111mm/77.75mmGood    
  38   Sun Oct 23 16:46:05 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa822 111mm/77.75mmGoodLong run

stopped for access

 
  
  37   Sun Oct 23 15:35:42 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa821 111mm/77.75mmGoodLong run

FEI4 crashed

restarted
  
  Draft   Sun Oct 23 15:14:30 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa821 111mm/77.75mmGood    
  35   Sun Oct 23 15:14:09 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa821 111mm/77.75mmGoodLong one, stopped for access of the other
users
  
  34   Sun Oct 23 13:48:33 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa820 111mm/77.75mmGoodLong one, stopped for access of the other
users
  
  33   Sun Oct 23 12:06:50 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa819 111mm/77.75mmGoodLong one, stopped for access of the other
users
  
  32   Sun Oct 23 11:31:58 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa818 111mm/77.75mmUnknownanother short one because the fei4 is so
reliable :)
  
  31   Sun Oct 23 11:29:43 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa817 111mm/77.75mmGoodanother short one because the fei4 is so
reliable :)
  
  30   Sun Oct 23 11:18:19 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa816 111mm/77.75mmGoodshort run from 11:10 to 11:18

 

fei4 crashed
  
  29   Sun Oct 23 11:14:44 2022 RD50 Generic Userbeam start time       beam stared at 11:10 events and particles
counting up
  
  28   Sun Oct 23 10:07:44 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa815 111mm/77.75mmGoodOvernight run

New Firmware with 64bit TS

FEI4 with busy (with timing for
  
  27   Sat Oct 22 21:11:13 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa814 111mm/77.75mmGoodNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  26   Sat Oct 22 21:11:04 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa813 111mm/77.75mmGoodNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  25   Sat Oct 22 21:10:24 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa810-812 111mm/77.75mmCrapNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  24   Sat Oct 22 16:42:51 2022 Christian IrmlerMikrotik Router Confignone      Backup of Mikrotik Router configuration.

Binary and rules as script
 rd50_tb_h6b-20221022.backuprd50_tb-h6b-20221022.rsc 
  23   Sat Oct 22 14:55:06 2022 RD50 Generic UserSyncable data runHEPHY_DUT11.2FEi4 | Mimosa809 111mm/77.75mmUnknownNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  22   Sat Oct 22 14:07:34 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa808 111mm/77.75mmUnknownRepeat of ID 20 as it was interrupted

New Firmware with 64bit TS

FEI4 without busy
  
  21   Sat Oct 22 11:36:53 2022 RD50 Generic Usert0 testsHEPHY_DUT11.2FEi4 | Mimosa786-807 111mm/77.75mmCrapt0 tests   
  20   Sat Oct 22 10:01:21 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa785 111mm/77.75mmUnknownNew Firmware with 64bit TS

FEI4 without busy
(test if the FEI4 kills th run)
  
  19   Sat Oct 22 09:33:06 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa784 111mm/77.75mmUnknownNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  18   Sat Oct 22 09:30:17 2022 RD50 Generic UserSYSTEM TESTHEPHY_DUT11.2FEi4 | Mimosa781-783 111mm/77.75mmCrapSystem test checking if the TLU sends triggers
without terminating the Runcontrol (answer:
No)
  
  17   Fri Oct 21 19:23:28 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa780 111mm/77.75mmUnknownNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  16   Fri Oct 21 19:22:44 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa779 111mm/77.75mmCrapNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  15   Fri Oct 21 19:07:50 2022 RD50 Generic UserNight run testHEPHY_DUT11.2FEi4 | Mimosa778 111mm/77.75mmGoodNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  14   Fri Oct 21 18:59:05 2022 RD50 Generic UserFEI4 busy testHEPHY_DUT11.2FEi4 | Mimosa777 111mm/77.75mmGoodNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  13   Fri Oct 21 18:37:26 2022 RD50 Generic UserFEI4 busy testHEPHY_DUT11.2FEi4 | Mimosa776 111mm/77.75mmCrapNew Firmware with 64bit TS

FEI4 with busy (with timing for
tracking)
  
  12   Fri Oct 21 18:36:50 2022 RD50 Generic UserFEI4 busy testHEPHY_DUT11.2FEi4 | Mimosa775 111mm/77.75mmGoodNew Firmware with 64bit TS

FEI4 without busy (no timing for
tracking)
  
  11   Fri Oct 21 15:25:54 2022 RD50 Generic UserSYSTEM TESTHEPHY_DUT11.2FEi4 | Mimosa760-774 111mm/77.75mmCrapSystem test   
  10   Fri Oct 21 15:24:45 2022 RD50 Generic Usershort data run with CPU TSHEPHY_DUT11.2FEi4 | Mimosa759 111mm/77.75mmGoodshould be the correct run, maybe it was
another. Firmware and software with CPU TS
  
  9   Fri Oct 21 15:24:04 2022 RD50 Generic UserSYSTEM TESTHEPHY_DUT11.2FEi4 | Mimosa757-758 111mm/77.75mmCrapSystem test   
  8   Fri Oct 21 13:31:58 2022 RD50 Generic UserSYSTEM TESTHEPHY_DUT11.2FEi4 | Mimosa753-756 111mm/77.75mmCrapSystem test   
  7   Fri Oct 21 10:49:30 2022 RD50 Generic UserSYSTEM TESTHEPHY_DUT11.2FEi4 | Mimosa752 111mm/77.75mmCrapSystem test   
  6   Fri Oct 21 10:49:15 2022 RD50 Generic UserSYSTEM TESTHEPHY_DUT11.2FEi4 | Mimosa751 111mm/77.75mmCrapSystem test   
  5   Fri Oct 21 10:48:24 2022 RD50 Generic UserSYSTEM TESTHEPHY_DUT11.2FEi4 | Mimosa750 111mm/77.75mmCrapSystem test   
  4   Thu Oct 20 22:18:23 2022 RD50 Generic Usernight run with DUTHEPHY_DUT11.2FEi4 | Mimosa7491.25M111mm/77.75mmGoodOld software version -> No timestamp
overflow or 64bit counter

Will try to fix software tomorrow
  
  3   Thu Oct 20 22:06:26 2022 RD50 Generic Usernight run with DUTHEPHY_DUT11.2FEi4 | Mimosa74862k on TLU111mm/77.75mmGoodOld software version -> No timestamp
overflow or 64bit counter

Will try to fix software tomorrow
  
  2   Thu Oct 20 22:05:18 2022 RD50 Generic Usershort test with FEI4none-FEi4 | Mimosa747 111mm/77.75mmGoodNeeds to be checked for data integrity
with FEI4
  
  1   Thu Oct 20 22:00:22 2022 RD50 Generic UserLong Night Run (Mimosa)none-Mimosa710 111mm/77.75mmGoodNeeds to be checked for data integrity   
ELOG V3.1.5-fc6679b